Showing results: 106 - 120 of 144 items found.
-
369A910 -
Di-Log
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
Di-Log
Our clamp meters measure both high and low AC and DC currents as well as earth leakage and earth resistance. With variable jaw sizes, max current readings up to 2000A AC/DC and features including TRMS, data logging and temperature readings we have clamps suitable for a wide range of electrical applications.
-
1630-2 -
Fluke Corporation
The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.
-
Accumetrics Associates, Inc.
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
MI 3152 EurotestXC -
Metrel d.d.
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.
-
Fluke Corporation
Fluke''s family of earth ground testers have been built to address the entire spectrum of ground testing methods from the basic to the most advanced. Our testers have been designed to be accurate, safe and easy to use. We provide quick and precise resistance measurements through several test methods: 3- and 4-pole Fall-of-Potential testing, selective testing, stakeless testing and 2-pole testing. Detailed application information can be found at the Earth Ground Solution Center.
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
PowerCheck 1557 -
Seaward Electronic Ltd
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
COMBI521EV -
HT Italia Srl
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
MI 3100 SE EurotestEASI -
Metrel d.d.
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
GEOHM Series -
GMC-I Messtechnik GmbH
Three or four-pole measuring method1-Clamp Measurement (optional)2-Clamp Measurement (optional)Rechargeable battery operation (optional)Digital displayRobust housingNo balancing requiredContinuous monitoring of interference voltage and auxiliary earth electrode resistance with indication if allowable limit values are violatedData storage for 250 measurements (1000 measured values)Data interface for transmission of measured values to a PCSoftware (optional accessory) for measured value storage at a PC
-
44500 -
M. C. Miller Company
Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source